InstructionManualInstruction ManualTotal Construction SolutionsPENTAX Industrial Instruments Co.,Ltd.2-5-2 Higashi-Oizumi / Nerima-ku,Tokyo 178-0063,J
10CONTENTSafety PrecautionsPrecautions• 1. For proper use of the instrument 111.1 Standard configuration1.2 Description1.3 Unpacking1.4 Battery
111. For proper use of the instrument1.1 Standard configurationThe instrument (PLP-601 / PLP-602 /PLP-601R / PLP-602R)Detector (LS6)Rod Adapter (LA6)D
1.2 Description12Center markTop handleEmitting beam apertureKeypadDetachable knob for RotorBattery capBottom plate
13Plate VialBeam Reception WindowLCD DisplayIllumination Switch Buzzer Switch Accuracy Switch Power Switch IndexFixing KnobDetector Attaching Scr
141.3 UnpackingTaking the instrument out of the carrying caseGently set down the carrying case so that its cover is upward.Unlatch and open the case w
151.4 Battery insertionBattery insertion for the instrumentTurn the detaching knob for battery cap counterclockwise and remove the cap from the instru
16Battery insertion for the detectorLS6 DetectorSlide the battery cover while pushing its mark and remove it.Insert the accumulated dry battery
172.Display and Keypad2.1 Keypad2.2 Role of keys(1) Power supply key ONONOFFOFFBATTERY CHECK POWEROFFLEVELMANUALMODEBattery check keyRemaining battery
18(2) Battery check key Remaining battery display lamp NOTE:• When 4 pcs rechargeable batteries type D are used,only 2 green lamps are turned on even
19(3) Auto/manual change keyNOTE:• Simple grade setting can be done by manual mode,but usually performed without stopping the automatic self-leveling
20(4) Switching the rotation speed• Please switch the rotation speed after turning off the instrument power supply.[From 300 to 600 rpm]NOTE:• When th
2.3 Warning displayOff level display lamp turns on in red as warning display and rotation ofrotor and emission of laser beam stop under following situ
223. Preparation for measurement1.1 Setting up the tripod[Arranging the tripod]Prepare the normal tripod for Level instrument.The dome head type and e
23[Setting up the tripod]For an extension tripod,adjust the legs to a suitable length and secure the leg clamps.Spread the legs to a proper extent for
243.2 Setting up the instrument[Mounting on the tripod]Mount the instrument on the tripod head and while supporting the instrument with one hand,secur
253.3 Arranging the detector[Installing the rod adapter LA6]LS6 detectorMount the instrument on the rod adapter so that the guide pin of the rod adapt
264. Measurement4.1 Operating the instrument[Starting the operation]Press the power supply key.Automatic self-leveling function works and leveling beg
274.2 Operating the detector:LS6[Power switch]Push the power switch to turn on the power to the detector.Pushing the power switch again turns off the
28[Selecting the reference level detecting accuracy]Push the detection accuracy selection switch to select the needed detection accuracy.High accuracy
29[ON or OFF of the beam reception buzzer]Push the beam reception buzzer switch to select either the buzzer sounding or silenced.[Illuminating the dis
3Safety Precautions (must be followed)The following items are intended to prevent possible injury to the user orother people and/or damage to the inst
30[Detecting the reference level]At the measuring point,set the position of the detector nearly to the height of the beam emitting aperture of the ins
31[Direct marking]After the reference level has been detected,mark a line along the detector’s index,or its top or bottom end.[Plain rod marking]After
32[Reading the staff]After the reference level has been detected,read the staff,using the index on the rod adapter.NOTE:• When detecting the reference
335. Maintenance5.1 Maintenance after use[Stains on the main body]Brush dust off and wipe off moisture with tissue paper.Clean off any stains with a s
34[Handling the battery]If the instrument is not to be used for a long time,be sure to remove the batteries from the instrument and the detector and s
355.2 Check and adjustment of the datum point [Check]Set up the instrument on the tripod halfway between two walls or pillars about 40m away so that t
36Read the target plates on the walls (A,B) to detect the reference points.If the readings of the target plates differ less than ± 5 mm,the instrument
375.3 Troubleshooting PLP-601 / PLP-602 / PLP-601R / PLP-602RRotor Display Content Checking pointDisplay lamps are Battery capacity Replace with fres
38Detector LS6Rotor Display Content Checking pointCan rotate Cannot detect Battery capacity Replace with freshis low. battery.Incorrect battery Check
396. SpecificationsINSTRUMENT PLP-601R / PLP-602RAccuracy of reference beam: ± 10”(PLP-601/PLP-601R)± 12”(PLP-602/PLP-602R)Measuring range: Radius 1~2
4WARNING• While the instrument is operating,be careful not to expose your eyes to the emitting laser beam (red light source).Exposure to a laser beam
407. Notice to the user of this productTo assure compliance with the Safety Standard 21 CFR,Chapter I.Subchapter J.The U.S.bureau of Radiological Heal
Japan Surveying Instruments Manufacturers’ AssociationMember symbol of the Japan Surveying Instruments Manufacturers’Association representing the high
5PrecautionsThe instrument should not be stored or used in extreme temperatures orjob on a place subject to rapid change of temperature.(Refer to the
6Put into the carrying for storage and place in a dry area not subject to vibration,dust or high moisture.When storage and usage temperatures are wide
7The detector (option) may react to the Laser beam and further react to the Fluorescent lamp,Site lamp,modulated light or an electric wave (in or near
8The instrument should be stored in the carrying case and packed with cushioning material and handled with care as ‘Fragile’.Check the ‘check and adju
9Be sure to observe the items in the instruction manual for proper use of the instrument.Please replace attached batteries with new ones before you wo